1.
Biomed Chromatogr ; 33(2): e4403, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30276833

RESUMO

Beraprost sodium is an oral prostacyclin analog that was first approved in 1992 (Japan) for the treatment of peripheral vascular disorders. It is administered orally as a tablet available in strength 20 µg. In this paper, we described a liquid chromatography tandem mass spectrometry method that was developed for the quantification of beraprost in human plasma with high sensitivity at picogram per milliliter concentration. The method had been validated in terms of selectivity, sensitivity, accuracy and precision, matrix effect, linearity, recovery and carry-over according to the Guideline on Bioanalytical Validation from the European Medicines Agency. The standard calibration curve for beraprost was 9.5-1419 pg/mL. This method has been applied successfully to a bioequivalence study with 60 µg of beraprost (three tablets) in 29 healthy volunteers. The results showed that the two formulations of beraprost are bioequivalent.


Assuntos
Cromatografia Líquida/métodos , Epoprostenol/análogos & derivados , Espectrometria de Massas em Tandem/métodos , Epoprostenol/sangue , Epoprostenol/química , Epoprostenol/farmacocinética , Humanos , Modelos Lineares , Inibidores da Agregação Plaquetária/sangue , Inibidores da Agregação Plaquetária/química , Inibidores da Agregação Plaquetária/farmacocinética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Equivalência Terapêutica